1. kamere
  2. Car Audio & Electronics
  3. Domači glasbeni sistem
  4. Osebni avdio
  5. televizorji
  6. Pametni dom
  >> Elektronske tehnologije Online >  >> Pametni dom >> Klima

Klimatska naprava pušča vodo na tla? 5 Vzroki za kapljanje Split AC

Ne sploh normalno. Če vidite, da voda pušča iz naprave za obdelavo zraka in teče po steni na tla, je nekaj narobe z notranjo enoto AC. Preverili bomo vseh 5 krivcev, ki povzročajo puščanje vode iz klimatske naprave od spodaj in razložite, kako popraviti vaš vodnik za kapljanje zraka.

Najprej je pomembno opozoriti, da vodoravna stenska AC enota pušča vodo v notranjosti ni dober znak. Če vidite vodne kapljice ali celo vodo teče po steni iz mini split notranje enote, takoj izklopite klimatsko napravo.

Potem morate preveriti vse te pogoste razloge, zakaj voda uhaja iz zbiralnika pod napravo za obdelavo zraka (pokazali vam bomo, kako enega za drugim in kako popraviti puščajočo napravo za obdelavo zraka v nadaljevanju):

  1. Zamašena kondenzacijska cev regulatorja zraka (v celoti ali delno). To je vzrok številka 1 za puščanje vode iz klimatske naprave.
  2. Luknja v odtočni posodi. Če je odtočna posoda pod napravo za obdelavo zraka poškodovana, lahko voda uhaja iz notranje enote AC in pod napravo za obdelavo zraka boste videli vodni madež.
  3. Nedelujoča kondenzacijska črpalka. Nekateri notranji mini razdelilniki imajo črpalko, ki pomaga pri odvajanju odtočne posode za pripravo zraka. Če črpalka ne deluje pravilno, bo voda začela uhajati iz naprave za obdelavo zraka na tla.
  4. Umazani zračni filtri povzročajo zmrzovanje notranjih AC tuljav. Če je pretok zraka omejen zaradi umazanih filtrov, ki omogočajo vedno manj CFM, lahko tuljave uparjalnika v napravi za obdelavo zraka zmrznejo. Ko se ta led tali, je lahko kondenzacijski vod, odtočna posoda ali kondenzacijska črpalka preobremenjena in voda se bo razlila po odtočni posodi. To bomo opazili, ko naprava za obdelavo zraka pušča vodo na tla.
  5. Nizke ravni hladilnega sredstva. Podobno kot pri umazanih zračnih filtrih lahko nizke ravni freona povzročijo zamrznitev notranjih AC tuljav. Ko se stopijo, bo količina sproščene vode prevelika, da bi jo lahko obvladali, in naprava za obdelavo zraka bo začela puščati vodo od spodaj.

Če vidite vodne madeže na steni pod krmilnikom zraka, je vaša notranja AC enota prizadeta zaradi enega (ali več) od teh krivcev. Do uhajanja v bistvu pride zaradi dveh glavnih razlogov:

  1. Neustrezna drenaža (vzroki #1, #2 in #3 spodaj). To bo povzročilo kapljanje vode iz razdeljene notranje enote AC.
  2. Preveč vode zaradi odmrzovanja tuljav uparjalnika AC (vzroka št. 4 in št. 5 spodaj).

Da bi vsem pomagali, bomo pregledali te krivce enega za drugim , ki poudarja, zakaj naprava za obdelavo zraka pušča vodo in kako lahko sami popravite stensko klimatsko napravo, ki pušča vodo v zaprtih prostorih (DIY).

Če sumite, da imate težave št. 3 in št. 5, boste verjetno morali poklicati osebo za HVAC. Na koncu podajamo nekaj predlogov o HVAC fantih na vašem območju, če jih potrebujete.

Začnimo z najpogostejšim razlogom za puščanje vode iz klimatskih naprav na tla pod notranjo klimatsko enoto:

Št. 1. Zamašena ali delno blokirana kondenzacijska cev naprave za obdelavo zraka

Ko HVAC fantje slišijo 'mini split AC kaplja voda notri' , najprej pomislijo na zamašen kondenzacijski vod. To je zato, ker v več kot 60 % primerov , razlog, zakaj naprava za obdelavo zraka v zaprtih prostorih pušča vodo, je blok v tej vrstici.

Vse mini-split AC enote delujejo tudi kot razvlaževalec (poleg hlajenja). Ko gre topel notranji zrak preko hladnih tuljav uparjalnika znotraj naprave za obdelavo zraka, se zgodi dvoje:

  1. Zrak se ohladi.
  2. Moisture in the air is condensed on the coils , thereby reducing indoor relative humidity levels.

This water will drip from the evaporator coils to a drip pan, located at the bottom of a mini split air handler. From there, the accumulated water is drained outside via the condensation line (with or without the assistance of a condensate pump, more about that under #3 culprit).

Now, if you see a lot of water in the drip pan under the air handler, you probably have a clog inside the condensation line . Over time, dirt, dust, and even mold will block the condensation line. If this line can’t remove the condensate adequately, the water from the air handler drip pan will start to leak out of the fan onto the wall below the air handler and finally reach the floor.

Solution: If your split AC indoor unit is dripping water due to a clogged condensation line, you have to unclog that line. This might sound simple but it can be quite a hassle to unclog a condensation line.

Here are the step-by-step instructions on how you do that (Carrier has a useful article on how their HVAC technicians unclog lines here):

  1. Turn the air conditioner off.
  2. Locate the condensation drain pipe. It’s usually located at the bottom of the air handler (leading from the drain pan to outdoors with the pipe going through the wall). You will see a small hole in the drain pan (about 1/2 inches in diameter). This is the drain pipe opening.
  3. If you find water standing in the drain pan, you will have to remove it. You can do that with a rag or use a wet vac to suck it all out.
  4. Clean the drain pipe opening , if there are any visible clogs there.
  5. Clean all the drain pipe by using a dry vacuum or wet vacuum. If there was a clog in your pipes, you will see that clog being sucked out by the vacuum. If you don’t have these vacuums, you can also use a garden hose to remove the blockage.
  6. Check if the clogging was removed. Just take a small amount of water and pour it down the drain pipe. If you see that water coming out in the outdoor pipe end, the clog has been successfully removed.
  7. Optional: To make sure the clogging will not happen again, use a PVC piping cleaner and flush it down the pipe. If you don’t have PVC cleaner on hand, you can also use vinegar to clean the mini split AC drain pipe.

If there was a clog in the pipe (you sucked out black goo out of the pipe), it was causing the air handler to leak water inside. With the clog removed, you have successfully fixed the drip from the air handler. You can start the air conditioner again.

#2 Water Is Leaking Through A Hole In A Drain Pan

As we have mentioned under #1 cause, the drain pan accumulates the water before it can be safely piped outdoors. In some cases, we see a crack in this drain pan through which water drips from the air handler down the wall and on the floor.

There are several things that can create a hole in the drain pan, including physically piercing it with something, rusting, and so on. In most cases, older indoor AC air handlers can have a hole in the pan.

Solution: You have to fix that cracked drain pan in order to prevent water from leaking out of the air handler. Some basic measures include just tapping the hole where the water leaks out down with water-proof tape, using epoxy resin, or replacing the whole drain pan (useful and quite cheap if you have an older unit).

Once the cracked drain pan has been fixed, you should see that water has stopped leaking from the air handler.

#3 Condensate Pump Is Not Working As It Should

Some mini splits and heat pumps have a condensate pump. This pump expediates the drainage of the drain pan by pumping water outdoors (usually against gravity). You will usually see it installed in mini splits that are located on the lower floors or basements . On upper floors, the gravity will be enough to drain the accumulated water outdoors.

Needless to say, if the condensate pump in your split AC system is bust, the water will start to fill the drain pan until it spills over. We see this water spillage as water slowly dripping from split AC indoor units on low floors or in the basement.

Rešitev: First you need to check if the condensate pump is actually working or not. There is an insightful article about how to tell if the condensate pump is working properly by Blair’s Air here.

If you find out that the condensate pump is broken, you will likely need to replace it. Replacing a condensate pump in a mini split is not a simple DIY project; you will usually have to call your HVAC guy to check it out and replace it if needed.

When the condensation pump is working again, you shouldn’t see the water leaking from the indoor air handler anymore.

Now, all of these first 3 culprits were caused by inadequate drainage. The next 2 culprits we are going to cover are caused by excessive acute water production inside your air handler:

#3 Dirty Air Filters Causing A Frozen Air Handler Dripping Water Indoors

It is quite interesting to see how many air conditioner problems are caused by dirty air filters. If your air handler started leaking water on the floor, dirty AC filters might be the problem.

Here is how dirty filters can cause an acute rush of accumulation in mini split AC unit:

If the filters are dirty, the cold indoor evaporator coils (inside air handler) will get less airflow. Due to restricted airflow, the warm indoor air is not warming up the cooling coils quickly enough. This can lead to the indoor AC evaporator coil freezing over . You will start noticing that your AC unit started blowing warm air at first.

All that warm air going over the frozen coils will start thawing the ice. Needless to say, that ice will get turned into quite a lot of water; more than the air handler drip pan can handle. As a result, you will start to notice the water running out of the indoor air handler and dripping to the floor.

Solution: First of all, you have to shut off the AC unit and wait for all the ice to melt. During this period, take a rag and soap the water that is being generated in order to avoid that water flowing down the wall under the horizontal air handler and damaging it.

Afterward, look at the air filters. If you notice a lot of dirt on them, it is quite possible that airflow restriction and the consequently frozen AC evaporator coils, and too much water inside the drain pan were all caused by dirty air filters.

Replace the air filters. Most HVAC experts recommend air filters be replaced every 1-3 months anyway. If indeed dirty air filters cause the air handler to spill water under your split AC indoor unit, the problem should go away with the new filters.

However, there is another culprit that can cause the air handler to leak water indoors in much the same way:

#5 Low Refrigerant Levels Causing Air Handler Leaking

Low refrigerant levels can cause similar AC evaporator freezing and the consequent melting of ice, ending in water coming from the air handler. In short, if the refrigerant is leaking, a chain of events can lead up to ice accumulation on the evaporator coils.

When that ice melts, it will overwhelm the drain pipe, and you will see that the access water is leaking down from the wall AC unit.

Rešitev: As before you would wait for all the ice to melt. During that melting use something to soap up the water and avoid carpet or wall damage.

It is very hard to recharge a mini split freon by yourself. You will need professional help. If you suspect that your mini split has low refrigerant levels (R22, R410A, and so on), you should turn off the AC unit and call your HVAC guy. He or she will measure the freon pressure, and help you out with recharging your AC unit.

All in all, if you see your air handler leaking water all over a carpet on the floor, or on the walls, you are facing two potential problems:inadequate drainage or access water.

Hopefully, you can use the understanding of the causes of the leaking air handler above to fix the leakage yourself.

If you need some help, you can use this form here and get quotes from up to 4 vetted HVAC guys in your area that will help you with a leaking mini split AC indoor unit.

In short, it is not all that hard to find out why your air handler is leaking water and fix it (either DIY or calling HVAC professional).


  1. Prednosti in slabosti z ECM Air Handler
  2. 5 razlogov za puščanje vode iz klimatske naprave
  3. Kako namestiti split klimatsko napravo?
  4. Zakaj mi klimatska naprava pušča?
  5. Iz klimatske naprave pušča voda? 5 razlogov zakaj in njihove rešitve